Being told that there is less fluid around your baby can be worrying. In many pregnancies, low fluid is found on its own and the baby is healthy. In others, it can be a sign that the placenta is not working as well as it should or that the waters have broken, and the baby needs closer monitoring and a carefully planned birth.
This guide explains what oligohydramnios means, how amniotic fluid is measured, why fluid can be low, the tests you may be offered and what the research, including our own studies, tells us about the safest time for your baby to be born.
Key points
- Oligohydramnios means there is less amniotic fluid around the baby than expected for the stage of pregnancy.
- It is usually diagnosed on a scan when the deepest pocket of fluid is less than 2 cm, or the amniotic fluid index is less than 5 cm.
- In the third trimester, the most common reasons are the waters having broken, the placenta not working as well as it should, and going past the due date.
- Low fluid on its own is often found in healthy pregnancies, but it can be a sign that the baby needs closer monitoring.
- A growth scan with Doppler blood flow helps tell apart low fluid on its own from low fluid caused by a problem with the placenta.
- When low fluid is found at term, birth from 37 weeks is usually recommended.
What is amniotic fluid and why does it matter?
Amniotic fluid is the fluid that surrounds your baby in the womb. In the second half of pregnancy, most of it is made by your baby’s kidneys as urine, and your baby swallows it back again. It:
- cushions and protects your baby and the umbilical cord from bumps and pressure
- gives your baby room to move and stretch, which helps the muscles, bones and joints develop
- contains nutrients, such as proteins, sugars and minerals, and growth factors that support your baby’s development
- contains antibodies (immunoglobulins) and other natural substances that help protect your baby against infection
- is breathed in and out by your baby, which helps the lungs to grow and mature, ready for the first breath after birth
- is swallowed by your baby, which helps the lining of the stomach and bowel to mature, ready for feeding after birth
- helps keep your baby at a steady, warm temperature.
The amount of fluid increases until about 34 to 36 weeks and then gradually reduces towards the due date.

© The Pregnancy Clinic
How is the amount of fluid measured?
The amount of fluid is measured on an ultrasound scan in one of two ways:
| Method | How it is measured | Normal | Low fluid (oligohydramnios) |
|---|---|---|---|
| Deepest vertical pocket (DVP) | The depth of the single largest pocket of fluid | 2 to 8 cm | Less than 2 cm |
| Amniotic fluid index (AFI) | The depths of the largest pockets in the four quarters of the womb, added together | 5 to 24 cm | Less than 5 cm |
When there is no measurable pocket of fluid at all, this is called anhydramnios.

Normal range: 5th to 95th centile (Magann et al., 2000).
Both methods are widely used. A Cochrane review of four randomised trials including more than 3,000 women found that using the amniotic fluid index labelled about twice as many women as having low fluid, and led to twice as many inductions of labour, without any improvement in outcomes for the baby. For this reason, the deepest vertical pocket is the preferred measurement for deciding on care in many units, and we report both at our clinic.
What can cause reduced fluid?
In the third trimester, the most common reasons are:
- the waters having broken (rupture of the membranes), sometimes with only a slow leak that you may not notice
- the placenta not working as well as it should (placental insufficiency). When the baby receives less oxygen and nutrients, blood flow is directed to the brain and away from the kidneys, so the baby makes less urine. This is often seen together with a small baby (fetal growth restriction)
- going past your due date, as the amount of fluid naturally reduces after 40 weeks
- less often, dehydration or some medicines, such as anti-inflammatory painkillers (for example ibuprofen) or some blood pressure tablets.
When low fluid is found earlier in pregnancy, it may be due to a problem with the baby’s kidneys or bladder (such as kidneys that have not developed or a blockage to the flow of urine), or the waters breaking early. These are uncommon and need assessment in a fetal medicine unit.
In many pregnancies, no cause is found and the baby is otherwise well. This is called isolated oligohydramnios.
What tests will I have?
If your scan shows low fluid, the following help us understand why, and how well your baby is coping:
- an assessment to check whether your waters may have broken
- a growth scan to check your baby’s estimated weight and growth trajectory
- Doppler blood flow in the umbilical artery, which reflects the health of the placenta, and in the middle cerebral artery, which reflects your baby’s oxygenation
- a check of your baby’s kidneys and bladder, and the rest of the anatomy
- a check of your baby’s position, as babies are more often breech when the fluid is low.
What are the risks for my baby?
When low fluid is found on its own in the third trimester and your baby is growing well with normal Doppler blood flow, the outlook is usually very good. However, with less fluid around the baby, the umbilical cord can be squeezed more easily during contractions. Low fluid is therefore associated with a higher chance of:
- changes in the baby’s heart trace in labour (fetal distress), and needing an assisted or caesarean birth
- a low Apgar score at birth and admission to the neonatal unit
- the baby lying in a breech or other non-head-down position.
A review of 12 studies including almost 36,000 women found that, with isolated low fluid at term, caesarean birth was about twice as likely and admission to the neonatal unit about one and a half times as likely. In our study of more than 100,000 pregnancies scanned at 36 weeks, a deepest pocket of less than 2 cm was one of the findings that independently predicted a longer stay in the neonatal intensive care unit. In our research on babies’ position at 36 weeks, low fluid was also associated with a higher chance of the baby not being head down. And in our study of almost 2,000 women having an induction of labour at term, the amount of fluid was one of the factors that helped predict the need for a caesarean section because of concerns about the baby’s heart trace.
The risks are higher when low fluid is caused by a problem with the placenta or the baby is small, and much higher when severe low fluid starts early in pregnancy, as the baby’s lungs and joints need fluid to develop normally.
When should my baby be born?
The best time for birth depends on the stage of pregnancy, the cause of the low fluid, your baby’s growth and the Doppler findings. The options for birth to consider are as follows:
| Finding | Options for birth to consider |
|---|---|
| Low fluid on its own at term, with normal growth and Doppler | Birth can be considered from 37 weeks, usually by induction of labour, after discussing the pros and cons of all management options |
| Low fluid before 37 weeks, with normal growth and Doppler | Closer monitoring with regular scans of fluid, growth and Doppler, and birth from 37 weeks |
| Low fluid with a small baby or abnormal Doppler | Timing guided by the growth and Doppler findings, as for a growth-restricted baby |
| Low fluid because the waters have broken | Care guided by your maternity unit, as for broken waters before labour |
Because the cord is more easily squeezed when there is less fluid, continuous monitoring of your baby’s heart rate in labour is usually recommended. Many women with low fluid have a vaginal birth after induction of labour.
Is there anything I can do?
Drinking plenty of water has been shown to increase the amount of fluid slightly, and it is sensible to stay well hydrated, especially in hot weather. However, it does not treat the cause, and it does not replace monitoring. Please avoid anti-inflammatory painkillers such as ibuprofen in pregnancy unless advised by your doctor.
Most importantly, please contact your maternity unit straight away if you notice your baby’s movements slowing down, changing or stopping, or if you think you may be leaking fluid.
Frequently asked questions
Does low fluid mean something is wrong with my baby?
Not necessarily. Low fluid is often found on its own in healthy pregnancies, particularly close to or after the due date. A growth scan with Doppler helps tell apart low fluid on its own from low fluid caused by a problem with the placenta.
Can the amount of fluid go back to normal?
Yes. The amount of fluid can vary from day to day, and a repeat scan sometimes shows a normal amount. This is why the findings are interpreted together with your baby’s growth and Doppler blood flow.
Will drinking more water help?
Drinking plenty of water may increase the fluid slightly and is sensible, but it does not treat the cause and does not replace monitoring.
Could my waters have broken without me knowing?
Sometimes a slow leak of fluid can be mistaken for urine or discharge. If you notice fluid leaking or your underwear is repeatedly wet, please contact your maternity unit to be checked.
Will I need a caesarean section?
Not usually. Many women with low fluid have a vaginal birth, often after induction of labour, with continuous monitoring of the baby’s heart rate. A caesarean section may be recommended if there are other concerns.
Should I monitor my baby’s movements?
Yes. Please contact your maternity unit straight away if your baby’s movements slow down, change or stop. Do not wait until the next day, and do not rely on a home heartbeat monitor.
Can I have a private scan alongside my NHS care?
Yes. Private scans are in addition to your NHS care, not instead of it. You will receive a written report to share with your midwife and maternity team.
Our approach at The Pregnancy Clinic
At The Pregnancy Clinic in Sevenoaks, Kent, growth scans are carried out by fetal medicine specialists. If your scan shows low fluid, it includes:
- measurement of the fluid by both the deepest vertical pocket and the amniotic fluid index
- your baby’s estimated weight and centile, and growth trajectory if you have had earlier scans
- Doppler blood flow in the umbilical artery and middle cerebral artery
- a check of your baby’s kidneys, bladder, anatomy, position and the placenta
- a clear explanation on the day, and a written report with recommendations to share with your NHS maternity team.
Book a growth and Doppler scan
A consultant-led growth and Doppler scan gives you a clear picture of your baby’s growth, fluid and wellbeing, and helps plan the safest birth.
Book a growth and Doppler scan →The Pregnancy Clinic provides planned appointments only. If you have pain, bleeding, leaking fluid, reduced baby movements or any other urgent concern, please contact your local NHS maternity unit straight away, or call 999 in an emergency.
Related pregnancy guides
Clinical references
- Arechvo A, Demertzidou E, Adjahou S, Syngelaki A, Magee LA, von Dadelszen P, Nicolaides KH, Akolekar R. Routine 36-week scan: prediction of prolonged neonatal intensive care unit admission. Ultrasound Obstet Gynecol 2025;66:298–306
- De Castro H, Ciobanu A, Formuso C, Akolekar R, Nicolaides KH. Value of routine ultrasound examination at 35–37 weeks’ gestation in diagnosis of non-cephalic presentation. Ultrasound Obstet Gynecol 2020;55:248–256
- Fiolna M, Kostiv V, Anthoulakis C, Akolekar R, Nicolaides KH. Prediction of adverse perinatal outcome by cerebroplacental ratio in women undergoing induction of labor. Ultrasound Obstet Gynecol 2019;53:473–480
- Magann EF, Sanderson M, Martin JN, Chauhan S. The amniotic fluid index, single deepest pocket, and two-diameter pocket in normal human pregnancy. Am J Obstet Gynecol 2000;182:1581–8
- Nabhan AF, Abdelmoula YA. Amniotic fluid index versus single deepest vertical pocket as a screening test for preventing adverse pregnancy outcome. Cochrane Database Syst Rev 2008;(3):CD006593
- Shrem G, Nagawkar SS, Hallak M, Walfisch A. Isolated oligohydramnios at term as an indication for labor induction: a systematic review and meta-analysis. Fetal Diagn Ther 2016;40:161–173
This guide provides general information and does not replace individual medical advice. Recommendations may vary according to your scan findings, pregnancy history and clinical circumstances.